November 12, 2026

Toshiba to Supply Hybrid Battery Storage System for Mongolia’s Darkhan Solar Plant

Toshiba will pair a fast power battery with a conventional battery at Mongolia’s Darkhan solar plant, funded by Japanese grant aid, ESS News reported.

Electricity transmission pylons representing the grid connection for the hybrid battery storage system planned at Mongolia's Darkhan substation

Photo by Petr Ganaj on Pexels

Toshiba will supply a hybrid battery storage system combining two different battery chemistries for a 10-megawatt solar plant at the Darkhan substation in northern Mongolia, ESS News reported on October 26, 2026. Mongolia’s National Power Transmission Grid (NPTG), the state-owned transmission operator, owns the project, which is funded through a Japanese government grant aid package and is scheduled to begin operating in December 2027.

Toshiba has begun manufacturing the power-type battery system and is preparing the accompanying energy management system (EMS), according to ESS News, which cited the company’s announcement. No named officials were quoted in the original report.

How the hybrid battery storage system is built

The Darkhan project pairs two battery types with different jobs. A power-type battery, built around Toshiba’s SCiB cells with a lithium titanate oxide (LTO) anode, is rated at 2 MW and 667 kWh, giving it a 20-minute discharge duration at a 3C rate. ESS News reported that this unit is intended for high-frequency solar ramp control, smoothing the rapid swings in output that solar generation produces as cloud cover changes.

A separate capacity-type battery, also rated at 2 MW but with 15.33 MWh of storage, discharges over about 7.66 hours. ESS News said this battery is likely sourced from a third-party lithium iron phosphate (LFP) supplier rather than Toshiba, and it is designed for peak shifting and supply-demand balancing across the day.

Toshiba’s energy management system will forecast solar generation and power demand to coordinate the two batteries, with remote monitoring and control available from both NPTG’s Ulaanbaatar headquarters and its Darkhan branch office.

Component Power Energy Duration Chemistry Role
Solar PV plant – 10 MW – – Generation
Power-type battery 2 MW 667 kWh 20 minutes (3C) Lithium titanate oxide (Toshiba SCiB) High-frequency solar ramp control
Capacity-type battery 2 MW 15.33 MWh about 7.66 hours Likely third-party LFP Peak shifting, supply-demand balancing
Architecture of the Darkhan hybrid battery storage system: solar plant, energy management system, two battery types, and grid connection Solar PV plant 10 MW Energy Management System (EMS) Power-type battery (SCiB) 2 MW / 667 kWh, 20 min Capacity-type battery 2 MW / 15.33 MWh, 7.66 hr Darkhan substation / NPTG grid
The Darkhan hybrid battery storage system pairs a fast power-type battery with a slower capacity-type battery, coordinated by Toshiba’s energy management system, to support the 10 MW solar plant feeding Mongolia’s NPTG grid. Source: ESS News, October 26, 2026.

Why pair two battery chemistries in one hybrid battery storage system

Running a fast-responding power-type battery alongside a slower capacity-type battery is meant to reduce cycling stress on the larger unit. ESS News reported that the power-type battery absorbs the rapid, high-frequency fluctuations in solar output, while the capacity-type battery handles the slower task of shifting energy from times of high generation to times of high demand. Splitting these two jobs between purpose-built batteries is intended to extend the working life of the capacity-type unit, which carries by far the larger share of stored energy.

The project sits within Mongolia’s wider push to expand renewable generation. ESS News noted that the country aims for renewables to reach 30 percent of total installed generation capacity by 2030. NPTG’s network, which the hybrid storage system will connect to, already spans 16 provinces and 300 districts through roughly 80 substations, according to publicly available company information. Across the border, China has pursued a similar pairing of generation and storage at far larger scale, with construction contracts awarded for a 1 GW wind-solar-hydrogen project in Inner Mongolia. The choice between fast power-type and slower capacity-type batteries at Darkhan also illustrates a distinction covered in more depth in an explainer on grid-scale battery storage duration and chemistry.

Background on Toshiba’s SCiB battery and Mongolia’s grid operator

Toshiba engineers developed the SCiB in 2011, according to the company’s own description of the technology. The battery uses a lithium titanium oxide chemistry that the company says resists thermal runaway and lithium metal plating, degrades minimally over tens of thousands of charge-discharge cycles, and can be charged quickly. Toshiba has since supplied SCiB-based systems for applications beyond grid storage, including emergency power systems on Tokyo Metro’s Ginza Line, where 40 trains introduced from April 2016 have used SCiB-based systems to power evacuation runs to the nearest station during outages.

That kind of pairing has become more common globally as storage deployment accelerates; global battery storage additions reached a record 108 GW in 2025, according to the International Energy Agency. NPTG, Mongolia’s national transmission grid operator, was founded in 1967 and is based in Ulaanbaatar. The state-owned company operates high-voltage transmission lines at 220 kV, 110 kV, and 35 kV through five regional branch offices. The Darkhan project extends NPTG’s grid into battery-backed solar generation as Mongolia works toward its 2030 renewable energy target, a step that depends on exactly the kind of hybrid storage system Toshiba is now building for the Darkhan substation.


Sources: ESS News; pv magazine

Featured image: photo by Petr Ganaj on Pexels (free Pexels license).